Steel BeamInstallers
Brickwork propped above a window while a cracked lintel is replaced

Lintel replacement · Kettering

Lintel replacement in Kettering

Lintel replacement in Kettering, from free survey to completion certificate.

  • Price fixed in writing once scope is agreed
  • Building control arranged
  • Temporary works and making good included

Free survey in Kettering

Tell us about the lintel replacement job in Kettering.

Please enter your name.
Please enter a UK phone number.
Please enter a valid email.
Please enter a UK postcode.
Please tell us a little about the job.
  • Free survey visit
  • Engineer's calculations arranged
  • Building control handled
  • Fixed written price once scope is agreed
  • England, Wales, mainland Scotland & NI

About our lintel replacement service in Kettering

We cover lintel replacement in Kettering (NN14, NN15, NN16) and the streets around it. Kettering is around 12.2 miles from Northampton, and we cover both. Each job is designed by a structural engineer and approved through local building control before work begins.

A lintel is the short beam that carries the brickwork over a window or door. When it fails, the signs tend to show outside first: a crack stepping up from the corner of the frame, a dip in the brick courses, or a window that has started to bind. Timber, concrete and old steel lintels each fail in their own way, but the fix follows the same principle.

Things to plan for

  • Cables for outside lights, burglar alarms and doorbells often run just above window and door heads. These are noted at the survey and made safe by an electrician before the brickwork is opened up, then reinstated afterwards.
  • Windows and doors can often stay in place during a lintel replacement, keeping the house secure and weathertight. Where a frame has been carrying sagging brickwork for some time, it may need adjusting or replacing once the new lintel takes the load.
  • Ground-floor lintels can usually be replaced from the ground with props alone. Openings on upper floors need scaffolding or a tower, which adds time and cost but also gives a safe, stable platform for rebuilding the brickwork neatly.
  • Many Victorian and Edwardian houses have a timber lintel hidden behind a decorative brick arch or on the inner face of the wall. Damp from leaking gutters or failed pointing can rot it unseen until the brickwork above starts to drop.
  • A typical single lintel takes a day or two on site. Keep the building control completion certificate with your property papers, because buyers' surveyors often notice old cracking around openings and their solicitors will ask what was done about it.

What happens, step by step

  1. Survey in Kettering

    We visit, look at the wall and what sits above it, measure the opening and note services, access and how the steel can be brought in.

  2. Engineer's design

    A structural engineer sizes the beam, padstones and any posts, and sets out the temporary support needed while the wall is out.

  3. Building control

    We submit a building notice or full plans application to the local council's building control team, so approval is in place before the wall is touched.

  4. Install and sign-off

    Props go in, the opening is formed, the steel is set and packed, building control inspects it, and we make good.

How much should I budget in Kettering?

As a guide, budget £390–£1,180 per lintel including VAT for lintel replacement in Kettering, based on published UK cost guides adjusted for prices in the East Midlands (-2%).

JobTypical guide rangeWhat it usually covers
Lintel replacement£390–£1,180 per lintelPropping, removing the old lintel, new lintel set on beds and brickwork made good
Widening an internal doorway£980–£2,450Opening widened with a new lintel or short beam, approval where structural, and making good
Plastering and making good£290–£1,180Boxing the beam, bead and skim, reveals, floor infill where the wall stood and tidy-up
Steel beam replacement£1,950–£5,400Propping, removing the failed beam, new steel on proper bearings, approval and making good

Figures include our approximate regional adjustment for prices in the East Midlands (-2%) and are rounded. How these figures are worked out.

Approvals in Kettering

For Kettering, building control is provided by the local council's building control team, or by a registered building control approver if preferred. We send them the engineer's calculations with a building notice or full plans application and book the inspections. Work done without approval can cause problems at sale and is far dearer to put right later.

If the beam bears into a wall you share with a neighbour, the Party Wall etc. Act 1996 applies, and a party structure notice must be served at least two months before that work starts. We arrange this through a party wall surveyor.

Building rules in England

Lintel replacement near Kettering

Local questions answered

How soon can lintel replacement start in Kettering?

Start dates depend on the engineer's calculations, the building control approval and, where needed, party wall notice periods. We give you a realistic timetable after the survey and keep you updated as each approval comes through.

Can you work on older or listed homes in Kettering?

Yes. Older homes often have lime mortar, timber lintels or shallow footings, which the engineer allows for. Listed buildings need listed building consent for internal structural changes as well as building regulations approval, and that must be in place first.

Why is my concrete lintel cracking and flaking?

Usually because the steel reinforcement inside has rusted. Rust takes up more space than steel, so it pushes the concrete cover off, exposing more steel to damp and speeding up the damage. An engineer checks whether the lintel can still do its job, but in many cases replacement is the sensible fix.

Can a lintel be replaced without removing the window?

Often, yes. The brickwork above is propped, the old lintel is taken out and the new one fitted while the frame stays in place under protection. If the frame has been carrying weight because the old lintel sagged, it may need easing or adjusting once the new lintel is in.

What type of lintel will be fitted?

The engineer decides, based on the opening width, the wall construction and the load above. Steel lintels are common in cavity walls, while solid walls or wide openings may suit a different type or a steel section. We fit what the specification calls for rather than a one-size option.

How much does lintel replacement cost in Kettering?

As a guide, budget £390–£1,180 per lintel including VAT for lintel replacement in Kettering, based on published UK cost guides adjusted for prices in the East Midlands (-2%). The exact figure depends on the span, what the wall carries, access and the finish, and is fixed in writing once the scope is agreed.

Planning to take a wall out?

Book a free survey visit. You get an itemised written quote covering calculations, building control, steel and making good.