Steel BeamInstallers
Brickwork propped above a window while a cracked lintel is replaced

Lintel replacement · Market Harborough

Lintel replacement in Market Harborough

Lintel replacement in Market Harborough, from free survey to completion certificate.

  • Itemised written quote
  • Beam sized by a structural engineer
  • Covering Market Harborough and nearby

Free survey in Market Harborough

Tell us about the lintel replacement job in Market Harborough.

Please enter your name.
Please enter a UK phone number.
Please enter a valid email.
Please enter a UK postcode.
Please tell us a little about the job.
  • Free survey visit
  • Engineer's calculations arranged
  • Building control handled
  • Fixed written price once scope is agreed
  • England, Wales, mainland Scotland & NI

Planning lintel replacement in Market Harborough

We cover lintel replacement in Market Harborough (LE16) and the streets around it. We also work in nearby Leicester, roughly 14.2 miles away. Each job is designed by a structural engineer and approved through local building control before work begins.

A lintel is the short beam that carries the brickwork over a window or door. When it fails, the signs tend to show outside first: a crack stepping up from the corner of the frame, a dip in the brick courses, or a window that has started to bind. Timber, concrete and old steel lintels each fail in their own way, but the fix follows the same principle.

Key points for your project

  • Many Victorian and Edwardian houses have a timber lintel hidden behind a decorative brick arch or on the inner face of the wall. Damp from leaking gutters or failed pointing can rot it unseen until the brickwork above starts to drop.
  • Concrete lintels fail when the steel reinforcement inside rusts and swells, pushing off the concrete face. Rust staining, flaking edges and exposed bars are the warning signs, and once that process is well under way an engineer will often recommend replacement over patching.
  • In cavity walls, a cavity tray and weep vents above the lintel send any water in the cavity back outside. Missing trays are a frequent cause of damp patches above window heads, so they are fitted as part of the replacement.
  • Windows and doors can often stay in place during a lintel replacement, keeping the house secure and weathertight. Where a frame has been carrying sagging brickwork for some time, it may need adjusting or replacing once the new lintel takes the load.
  • Cables for outside lights, burglar alarms and doorbells often run just above window and door heads. These are noted at the survey and made safe by an electrician before the brickwork is opened up, then reinstated afterwards.

What happens, step by step

  1. Free visit

    A short visit to Market Harborough to see the job, agree what you want and check the bearings, floors and services that affect the design.

  2. Calculations

    The engineer's calculations and a simple drawing are prepared for your opening and shared with you before anything is ordered.

  3. Building control

    We submit a building notice or full plans application to the local council's building control team, so approval is in place before the wall is touched.

  4. Steel in, made good

    On site we prop, open up, fit and pack the steel, then fire protect, box in and plaster once the inspection is done.

Guide prices for lintel replacement in Market Harborough

As a guide, budget £390–£1,180 per lintel including VAT for lintel replacement in Market Harborough, based on published UK cost guides adjusted for prices in the East Midlands (-2%).

JobTypical guide rangeWhat it usually covers
Lintel replacement£390–£1,180 per lintelPropping, removing the old lintel, new lintel set on beds and brickwork made good
Temporary works and propping£150–£490Props, spreaders, needles and sole plates for a typical opening, installed and struck
Rear wall opening for bi-fold or sliding doors£2,450–£6,850External wall opened up to about 5 m with steel, propping, cavity tray and making good (doors supplied separately)
Plastering and making good£290–£1,180Boxing the beam, bead and skim, reveals, floor infill where the wall stood and tidy-up

Figures include our approximate regional adjustment for prices in the East Midlands (-2%) and are rounded. How these figures are worked out.

Building control and neighbours in Market Harborough

Structural openings in English homes need building regulations approval before work starts. The local council's building control team can deal with it, or you can use a registered building control approver. Either way the steel is inspected before it is covered, and a completion certificate is issued at the end. Keep it safe for when you sell.

If the beam bears into a wall you share with a neighbour, the Party Wall etc. Act 1996 applies, and a party structure notice must be served at least two months before that work starts. We arrange this through a party wall surveyor.

Building rules in England

Lintel replacement near Market Harborough

Lintel replacement in Market Harborough: your questions

Do you also work near Market Harborough?

Yes. We also cover nearby towns including Corby, Kettering, Wigston Magna and Oadby.

Can you work on older or listed homes in Market Harborough?

Yes. Older homes often have lime mortar, timber lintels or shallow footings, which the engineer allows for. Listed buildings need listed building consent for internal structural changes as well as building regulations approval, and that must be in place first.

Why is my concrete lintel cracking and flaking?

Usually because the steel reinforcement inside has rusted. Rust takes up more space than steel, so it pushes the concrete cover off, exposing more steel to damp and speeding up the damage. An engineer checks whether the lintel can still do its job, but in many cases replacement is the sensible fix.

How long does lintel replacement take?

Most single openings take one to two working days on site, covering propping, removing the old lintel, fitting the new one and rebuilding the brickwork. Upper-floor lintels needing scaffolding, wide bay windows, and jobs where bricks must be sourced to match can all take longer.

What type of lintel will be fitted?

The engineer decides, based on the opening width, the wall construction and the load above. Steel lintels are common in cavity walls, while solid walls or wide openings may suit a different type or a steel section. We fit what the specification calls for rather than a one-size option.

What happens at the survey visit in Market Harborough?

We look at the wall, the floor and ceiling either side and what sits above, measure the opening you want, and note cables, pipes and access for the steel. It usually takes under an hour and there is no charge.

Planning to take a wall out?

Book a free survey visit. You get an itemised written quote covering calculations, building control, steel and making good.