
Kitchen-diner knock-throughs · London
Kitchen-diner knock-throughs in London
Calculations, approvals, propping, steel and making good for kitchen-diner knock-throughs across London.
- Itemised written quote
- Beam sized by a structural engineer
- Covering London and nearby
- Free survey visit
- Engineer's calculations arranged
- Building control handled
- Fixed written price once scope is agreed
- England, Wales, mainland Scotland & NI
Kitchen-diner knock-throughs in London: how it works
Kitchen-diner knock-throughs remove the wall between a kitchen and a dining room to create one open-plan room, with a steel beam carrying whatever the wall supported. The work is planned around the kitchen itself: gas, water, waste and extraction runs, where units and any island will go, and how the ceiling should look once the steel is in.
We carry out kitchen-diner knock-throughs throughout London, for homeowners, landlords and builders who need the structural part done properly. Towns we cover include Westminster, Enfield Town and Brent, among other places in the area. You get an itemised written quote that shows the calculations, approvals, steel, labour and finishing as separate lines.
Worth knowing before you start
- Taking the wall out removes the switches and sockets on it, and an open-plan room usually needs a new lighting layout. Electrical work in England must comply with Part P of the building regulations where it is notifiable, so rewiring is planned early.
- The structural work comes first, then first-fix electrics and plumbing, plastering, flooring and finally the kitchen fit. Booking the kitchen fitter only once the beam has passed inspection and the plaster has dried avoids units going onto damp walls.
- While the wall is out you will usually be without a working kitchen for several days. Many households set up a kettle, microwave and fridge in another room for that period and plan simple meals that need little cooking.
- Keep the structural calculations, the building control completion certificate and any gas or electrical certificates together. When the house is sold, the buyer's solicitor will usually ask for evidence that the knock-through was approved and signed off.
- Where the wall stood there is usually a strip of footing or a change in floor level between the two rooms. It is levelled with screed or timber so one continuous floor finish, such as tiles or engineered boards, can run straight across.
What happens, step by step
Free visit
A short visit to London to see the job, agree what you want and check the bearings, floors and services that affect the design.
Calculations
The engineer's calculations and a simple drawing are prepared for your opening and shared with you before anything is ordered.
Building control
We submit a building notice or full plans application to the local council's building control team, so approval is in place before the wall is touched.
Steel in, made good
On site we prop, open up, fit and pack the steel, then fire protect, box in and plaster once the inspection is done.
What do kitchen-diner knock-throughs cost in London?
As a guide, budget £3,200–£7,700 including VAT for kitchen-diner knock-through in London, based on published UK cost guides adjusted for London prices (+28%).
| Job | Typical guide range | What it usually covers |
|---|---|---|
| Kitchen-diner knock-through | £3,200–£7,700 | Internal structural wall between kitchen and dining room, steel beam, approvals and making good (kitchen fitting extra) |
| Structural calculations for a beam | £320–£960 | Site measure or photos, beam and padstone design and calculations for building control |
| Load-bearing wall removal with steel beam | £2,550–£6,400 | Typical internal wall up to about 4 m: calculations, building control, propping, steel, padstones, fitting, fire protection and making good |
| Steel column or post | £640–£1,920 per column | Column supplied and fitted with base and cap plates on a pad foundation |
Figures include our approximate regional adjustment for London prices (+28%) and are rounded. How these figures are worked out.
Approvals in London
In England, taking out a load-bearing wall or putting in a beam is building work under the Building Regulations 2010. It needs approval from building control, either the local council's building control team or a registered building control approver, through a full plans application or a building notice. Part A covers the structure and Part B covers fire safety, which is why steel in homes is usually fire protected.
If the beam bears into a wall you share with a neighbour, the Party Wall etc. Act 1996 applies, and a party structure notice must be served at least two months before that work starts. We arrange this through a party wall surveyor.
Kitchen-diner knock-throughs by town
- Brent
- Islington
- Westminster
- Bexley
- Barking
- Archway
- Sutton
- Croydon
- Ilford
- Enfield Town
- Harrow
- Tottenham
- Walthamstow
- Dagenham
- Becontree
- Romford
- Hayes
- Wembley
- Fulham
- Edmonton
- Southall
- Putney
- Battersea
- Purley
- Peckham
- Chingford
- Uxbridge
- Wimbledon
- Stamford Hill
- Brixton
- Hounslow
- Finchley
- Cricklewood
- Mitcham
- Feltham
- Acton
- Beckenham
- Chelsea
- Streatham
- South Croydon
Local questions answered
Can you work on older or listed homes in London?
Yes. Older homes often have lime mortar, timber lintels or shallow footings, which the engineer allows for. Listed buildings need listed building consent for internal structural changes as well as building regulations approval, and that must be in place first.
Which towns in London do you cover?
We cover towns including Brent, Islington, Westminster and Bexley, plus the villages and smaller towns around them.
Should I do the knock-through before or after fitting a new kitchen?
Before. The steel, any column, the floor levelling and the plastering all need to be finished first, so the kitchen fitter works in a dry, square room with services already in position. Fitting units and then taking out a wall risks damage and rework, and the beam position can affect where wall units go.
Can I have a kitchen island where the wall used to be?
Often you can, but it depends on whether the engineer needs a column and where the beam ends bear. If an island is part of the plan, tell us at the survey so the steel can be designed around it. Plumbing or power to an island also needs a route under the floor.
Who moves the gas pipe for my cooker?
A Gas Safe registered engineer, because work on gas pipework must legally be done by one. If the pipe runs in or near the wall being removed, it is capped or rerouted before demolition starts and reconnected once the new layout is in place. We build this into the programme so it is not left to chance.
Is the wall between my kitchen and dining room load-bearing?
It often is, particularly in older semis and terraces where it supports the bedroom floor joists. The clearest signs are joists bearing on it from above and a wall in the same position upstairs, but only an engineer's site check confirms it. We arrange that check as part of the survey and design stage.
Do I need a party wall agreement for kitchen-diner knock-throughs in London?
Yes, if the beam bears into a shared wall: the Party Wall etc. Act 1996 applies in England and Wales, and a party structure notice must be served at least two months before that work starts. We arrange it through a party wall surveyor.