Fire protection for steel beams · Stevenage
Fire protection for steel beams in Stevenage
Steelwork, approvals and making good for fire protection for steel beams in Stevenage and nearby.
- Itemised written quote
- Beam sized by a structural engineer
- Covering Stevenage and nearby
- Free survey visit
- Engineer's calculations arranged
- Building control handled
- Fixed written price once scope is agreed
- England, Wales, mainland Scotland & NI
What fire protection for steel beams involves in Stevenage
Planning fire protection for steel beams in Stevenage? Our team covers SG1, SG2, SG3 and SG4 and the streets around them. We also work in nearby Luton, roughly 9.3 miles away. You get one written quote for the calculations, approvals, propping, steel and making good.
A bare steel beam is strong at room temperature but loses much of its load-carrying capacity once it gets hot enough in a fire. If that beam holds up a floor or the walls above, it matters to everyone in the building. Fire protection slows the rate at which the steel heats up, buying time for people to get out safely.
Worth knowing before you start
- Building control treats fire protection as part of the structural approval, not an optional extra. If unprotected steel is found at inspection, the completion certificate is normally held back until the protection is in place and has been checked.
- Intumescent paint looks like an ordinary coating but swells into a thick insulating char when heated. How well it performs depends on the dry film thickness, which varies with the steel section and fire period, so it is applied to a written specification.
- Boxing is generally the lower-cost route for steel that will be hidden. Intumescent coatings cost more because of the product and the number of coats, and the price rises with the fire period and the size of the section.
- Fire boarding should not be cut into casually later on. Downlights, cables and pipes pushed through the boxing can weaken it, so services are planned before boarding, and any openings are sealed with suitable fire-stopping materials.
- A common fault is applying intumescent paint over the wrong primer, or over one of unknown type. The products must be compatible, so where steel was primed long ago the primer is identified or the surface is cleaned back before coating.
From survey to sign-off in Stevenage
Survey in Stevenage
We visit, look at the wall and what sits above it, measure the opening and note services, access and how the steel can be brought in.
Engineer's design
A structural engineer sizes the beam, padstones and any posts, and sets out the temporary support needed while the wall is out.
Building control
We submit a building notice or full plans application to the local council's building control team, so approval is in place before the wall is touched.
Install and sign-off
Props go in, the opening is formed, the steel is set and packed, building control inspects it, and we make good.
Guide prices for fire protection for steel beams in Stevenage
As a guide, budget £160–£640 per beam including VAT for fire protection to a steel beam in Stevenage, based on published UK cost guides adjusted for prices in the East of England (+6%).
| Job | Typical guide range | What it usually covers |
|---|---|---|
| Fire protection to a steel beam | £160–£640 per beam | Fire-rated board boxing or an intumescent coating system as specified |
| Structural calculations for a beam | £260–£800 | Site measure or photos, beam and padstone design and calculations for building control |
| Plastering and making good | £320–£1,270 | Boxing the beam, bead and skim, reveals, floor infill where the wall stood and tidy-up |
| RSJ supply and fit (single beam) | £850–£2,650 per beam | Beam supplied, delivered, lifted and packed on padstones, with propping (calculations and approval priced separately) |
Figures include our approximate regional adjustment for prices in the East of England (+6%) and are rounded. How these figures are worked out.
Approvals in Stevenage
For Stevenage, building control is provided by the local council's building control team, or by a registered building control approver if preferred. We send them the engineer's calculations with a building notice or full plans application and book the inspections. Work done without approval can cause problems at sale and is far dearer to put right later.
If the beam bears into a wall you share with a neighbour, the Party Wall etc. Act 1996 applies, and a party structure notice must be served at least two months before that work starts. We arrange this through a party wall surveyor.
Fire protection for steel beams near Stevenage
- Hitchin 4.8 mi
- Letchworth Garden City 5.4 mi
- Welwyn Garden City 6.9 mi
- Harpenden 8.8 mi
- Hertford 9.1 mi
- Luton 9.3 mi
Local questions answered
Can you work on older or listed homes in Stevenage?
Yes. Older homes often have lime mortar, timber lintels or shallow footings, which the engineer allows for. Listed buildings need listed building consent for internal structural changes as well as building regulations approval, and that must be in place first.
Do you cover Stevenage for fire protection for steel beams?
Yes. We carry out fire protection for steel beams in Stevenage and the SG1, SG2, SG3 and SG4 postcode districts. Book a free survey visit and we will check the wall, arrange the engineer's calculations and send an itemised written quote.
Does a steel column need fire protection as well as the beam?
Usually, if the column is part of the load path. A column carrying a beam is just as important in a fire, so it normally needs the same fire resistance. Columns are often boxed with board or coated with intumescent paint, and the engineer's design and building control confirm what applies to yours.
Can I box in a steel beam with normal plasterboard?
Not where fire protection is required. Standard plasterboard is not designed to protect steel for a set period in a fire. Fire-rated plasterboard is used instead, fixed in the number of layers and with the fixings the system specifies, so the boxing performs as intended and passes when building control checks it.
Will building control check the fire protection on my beam?
Yes. Building control looks at fire protection as part of the structural work, normally at or before the final inspection. For boxing they may want to see the board before it is skimmed, and for coatings they may ask for the product details and thickness readings. We keep these records ready for them.