Steel BeamInstallers
Victorian side return extension with grey steel beams and roof rafters

Side return extension steels · Somerset

Side return extension steels in Somerset

Side return extension steels across Somerset, designed by a structural engineer and signed off by building control.

  • Survey, design and installation in one
  • Covering BA1, BA10, BA11, BA16
  • Inspected before it is covered

Free survey in Somerset

Tell us about your side return extension steels project in Somerset.

Please enter your name.
Please enter a UK phone number.
Please enter a valid email.
Please enter a UK postcode.
Please tell us a little about the job.
  • Free survey visit
  • Engineer's calculations arranged
  • Building control handled
  • Fixed written price once scope is agreed
  • England, Wales, mainland Scotland & NI

Side return extension steels in Somerset: how it works

Side return extension steels are the beams and columns that replace the side wall of a terraced house's rear wing when the narrow passage beside it is built over. Sized by a structural engineer, they carry the wall, floor and roof loads above along the line of the old wall, so the kitchen and the infilled side return become one wide room.

Homes across Somerset range from Victorian terraces to post-war semis and newer estates, and side return extension steels look different in each. Coverage takes in Bath, Clevedon and Burnham-on-Sea and everywhere in between. We plan the steel, the temporary support and the approvals around the building, then fix the price in writing once the scope is agreed.

Worth knowing before you start

  • The kitchen is usually out of use while the side wall comes down and the frame goes in, so many households set up a temporary kitchen elsewhere in the house. The rest of the property normally stays in use throughout the steel stage.
  • Victorian outrigger walls are often a single brick thick in soft lime mortar, sometimes on very shallow footings. The engineer may ask for trial holes before deciding whether new foundations are needed under the column positions or beam ends.
  • Side returns often involve the Party Wall etc. Act 1996 in England and Wales, because the work sits right on the boundary. Building a new wall at the boundary, digging near a neighbour's foundations or cutting into a shared wall can each need notice.
  • The side wall of a typical outrigger carries the first-floor wall above it, and sometimes the rear wing's roof and the joists of the room over the kitchen. That is why taking it out calls for a beam along its full length.
  • Many outrigger kitchens have a chimney breast on the side wall being removed or on the party wall. Its position affects where beams can bear, and if any part of the breast is taken out, what remains above has to be supported as the engineer specifies.

How the job runs in Somerset

  1. Survey in Somerset

    We visit, look at the wall and what sits above it, measure the opening and note services, access and how the steel can be brought in.

  2. Engineer's design

    A structural engineer sizes the beam, padstones and any posts, and sets out the temporary support needed while the wall is out.

  3. Building control

    We submit a building notice or full plans application to the local council's building control team, so approval is in place before the wall is touched.

  4. Install and sign-off

    Props go in, the opening is formed, the steel is set and packed, building control inspects it, and we make good.

Guide prices for side return extension steels in Somerset

As a guide, budget £3,600–£8,750 including VAT for side return extension steelwork in Somerset, based on published UK cost guides adjusted for prices in the South West (+3%).

JobTypical guide rangeWhat it usually covers
Side return extension steelwork£3,600–£8,750Beams and posts along the old side wall line, propping and approvals (extension build extra)
Structural calculations for a beam£260–£770Site measure or photos, beam and padstone design and calculations for building control
Temporary works and propping£150–£520Props, spreaders, needles and sole plates for a typical opening, installed and struck
Steel column or post£520–£1,540 per columnColumn supplied and fitted with base and cap plates on a pad foundation

Figures include our approximate regional adjustment for prices in the South West (+3%) and are rounded. How these figures are worked out.

Approvals in Somerset

For Somerset, building control is provided by the local council's building control team, or by a registered building control approver if preferred. We send them the engineer's calculations with a building notice or full plans application and book the inspections. Work done without approval can cause problems at sale and is far dearer to put right later.

If the beam bears into a wall you share with a neighbour, the Party Wall etc. Act 1996 applies, and a party structure notice must be served at least two months before that work starts. We arrange this through a party wall surveyor.

Building rules in England

Local questions answered

Do you cover Somerset for side return extension steels?

Yes. We carry out side return extension steels in Somerset. Book a free survey visit and we will check the wall, arrange the engineer's calculations and send an itemised written quote.

What happens at the survey visit in Somerset?

We look at the wall, the floor and ceiling either side and what sits above, measure the opening you want, and note cables, pipes and access for the steel. It usually takes under an hour and there is no charge.

Can the steel beam be left exposed in a side return?

Yes, and many people like the look of exposed steel under a glazed roof. It usually still needs fire protection, so it is coated with an intumescent paint system to the specified thickness, then finished in your chosen colour. The engineer and building control confirm what protection is required.

Does a glazed roof affect the steel beam?

Yes. Glazed roofs need the beam they sit on to stay very straight under load, so the engineer may set a stricter deflection limit than for a solid roof. That can mean a deeper or heavier steel section, and the roof supplier's details need sharing early.

Do I need planning permission for a side return extension?

It depends on the house and where it is. Some side return infills can be built under permitted development, but the rules for side extensions are restrictive, and conservation areas and listed buildings add further controls. Check with your local planning authority or architect before committing to a design.

What steels do I need for a side return extension?

Usually a long beam along the line of the old outrigger side wall, often a second beam opening the back of the main house, and one or more columns where the loads meet. The exact arrangement depends on the house and the layout, and a structural engineer specifies every beam, column and connection.

Can I stay at home while the work is done in Somerset?

Usually, yes. The work area is screened and floors are protected. The rooms either side of the opening are out of action for a few days, and there is some noise and dust while the masonry comes out.

Planning to take a wall out?