Steel BeamInstallers
Steel beam half boxed in pink fire-rated plasterboard

Fire protection for steel beams · East Lothian

Fire protection for steel beams in East Lothian

Survey, engineer's design and installation of fire protection for steel beams anywhere in East Lothian.

  • Survey, design and installation in one
  • Covering EH21, EH31, EH32, EH33
  • Inspected before it is covered

Free survey in East Lothian

Tell us about your fire protection for steel beams project in East Lothian.

Please enter your name.
Please enter a UK phone number.
Please enter a valid email.
Please enter a UK postcode.
Please tell us a little about the job.
  • Free survey visit
  • Engineer's calculations arranged
  • Building control handled
  • Fixed written price once scope is agreed
  • England, Wales, mainland Scotland & NI

Fire protection for steel beams in East Lothian: how it works

Fire protection for steel beams is the layer of fire-rated board or intumescent coating applied to structural steel so it keeps its strength long enough in a fire for people to get out. Steel softens as it heats, so building regulations set a period of fire resistance for beams and columns, and the protection is chosen and applied to meet that period.

Fire protection for steel beams in East Lothian follows the same careful process wherever the property is: a survey, an engineer's design, the right approval and safe temporary works. Coverage takes in Tranent, Haddington and Dunbar and everywhere in between. We price it all up front so there are no surprises once the wall is open.

Key points for your project

  • Intumescent paint looks like an ordinary coating but swells into a thick insulating char when heated. How well it performs depends on the dry film thickness, which varies with the steel section and fire period, so it is applied to a written specification.
  • Keep a record of what was fitted: the board type and number of layers, or the coating product, thickness readings and number of coats. Building standards may ask for it, and it helps answer queries when the house is sold.
  • Steel does not burn, but it loses stiffness and strength as it heats. Protection is there to keep the temperature of the beam down for a set period, so the floor or walls it carries stay up while people leave.
  • Boarding is fairly clean work, but coatings need a clean, dry and well-ventilated room at a suitable temperature. Dust from other trades can spoil the surface, so painting is normally scheduled once the messy work in that room is finished.
  • Boxing is generally the lower-cost route for steel that will be hidden. Intumescent coatings cost more because of the product and the number of coats, and the price rises with the fire period and the size of the section.

How the job runs in East Lothian

  1. Look and measure

    We check the wall, the span you want and what the wall is carrying, and photograph anything the engineer needs to see.

  2. Design and price

    Calculations come back from the engineer and we confirm your fixed written price, line by line.

  3. Building warrant

    A building warrant is applied for from East Lothian Council, and work starts only once the warrant has been granted.

  4. Fit, inspect, finish

    The work is propped and the steel installed and packed tight. After inspection the opening is boxed, plastered and left clean.

Guide prices for fire protection for steel beams in East Lothian

As a guide, budget £140–£550 per beam including VAT for fire protection to a steel beam in East Lothian, based on published UK cost guides adjusted for prices in Scotland (-9%).

JobTypical guide rangeWhat it usually covers
Fire protection to a steel beam£140–£550 per beamFire-rated board boxing or an intumescent coating system as specified
Steel column or post£460–£1,360 per columnColumn supplied and fitted with base and cap plates on a pad foundation
RSJ supply and fit (single beam)£730–£2,280 per beamBeam supplied, delivered, lifted and packed on padstones, with propping (calculations and approval priced separately)
Building warrant fee£215–£435Statutory fee set by the estimated value of the work: £215 up to £5,000, rising on a sliding scale (fees from 1 April 2026)

Figures include our approximate regional adjustment for prices in Scotland (-9%) and are rounded. How these figures are worked out.

Approvals in East Lothian

Steel beam work in East Lothian needs a building warrant from East Lothian Council. The structural design is part of the application, and the council's building standards team accepts the completion certificate once the work is done as approved.

Scotland has no Party Wall Act. Work affecting a shared wall is governed by your title deeds and the general law, and in flats by the Tenements (Scotland) Act 2004, so it is sensible to agree the work with neighbours in writing before starting.

Building rules in Scotland

Fire protection for steel beams by town

Fire protection for steel beams in East Lothian: your questions

Do I need a party wall agreement for fire protection for steel beams in East Lothian?

There is no Party Wall Act in Scotland. Your title deeds and the general law apply instead, and the Tenements (Scotland) Act 2004 for flats, so agree the work with your neighbour in writing before it starts.

What happens at the survey visit in East Lothian?

We look at the wall, the floor and ceiling either side and what sits above, measure the opening you want, and note cables, pipes and access for the steel. It usually takes under an hour and there is no charge.

How long does intumescent paint take to apply?

Several days in most cases. Each coat has to dry before the next is applied, and the number of coats depends on the thickness needed. Cold or damp rooms slow drying, so the space is kept warm and ventilated, and the top coat goes on once the full build has been measured.

Does a steel column need fire protection as well as the beam?

Usually, if the column is part of the load path. A column carrying a beam is just as important in a fire, so it normally needs the same fire resistance. Columns are often boxed with board or coated with intumescent paint, and the engineer's design and building standards confirm what applies to yours.

Is boxing in a steel beam cheaper than intumescent paint?

Usually, yes. Boxing with fire-rated plasterboard tends to cost less for steel that will be hidden. Intumescent coatings generally cost more because of the product and the number of coats needed, but they let the beam stay visible. Where either method would work, both can be priced on the itemised quote so you can compare.

Will building standards check the fire protection on my beam?

Yes. Building standards looks at fire protection as part of the structural work, normally at or before the final inspection. For boxing they may want to see the board before it is skimmed, and for coatings they may ask for the product details and thickness readings. We keep these records ready for them.

Planning to take a wall out?